一级α片高潮视频-美国一级av片在线观看-一级亚洲看片鲁在线观看-男女一级A片大黄一进一出-日韩黄色三级片在线免费看-免费看三级片的网站-亚汌一级免费毛片-国产片婬乱一级毛片视频-一级a一级a爰片免费免免2021

Contact Us

Waterproof Cooling Fan Motor Protection

Date: 2015-2-27   Click: 1457 Times

From "Waterproof Cooling Fan" inside the motor is concerned, it has internal protection devices, there is a thermal circuit breaker is part of the coil windings shorted, resulting in a sharp increase in heat, open circuit breakers, motor under such circumstances, the general strike . This rarely happens. Another is to start capacitance becomes smaller, although the nameplate reads those parameters, but a long time, the capacitance is reduced, resulting in a starting torque "Waterproof Cooling Fan" motor is smaller, can not drive the load. This simple, remove the capacitors, go to a new one, the same model should be no problem. But the best for a 20% larger than the original, and will get better results. Motor shaft axial clearance is too large can cause can not drag the load. If you are disassembling the motor shaft axial gap is too large to be adjusted by adjusting the shims. When installing "Waterproof Cooling Fan" motor, the rotor and the bearing must be concentric job, slowly tightening the screws diagonally want, and then use a screwdriver to knock wood shaft, making concentric.

Back to: Industry news

+86-0769-83660708

Home Product News Contact