一级α片高潮视频-美国一级av片在线观看-一级亚洲看片鲁在线观看-男女一级A片大黄一进一出-日韩黄色三级片在线免费看-免费看三级片的网站-亚汌一级免费毛片-国产片婬乱一级毛片视频-一级a一级a爰片免费免免2021

Contact Us

Small Cooling Fan deviated

Date: 2015-1-27   Click: 1495 Times

When "Small Cooling Fan" operating conditions deviate the flow direction changes resulting in each blade angle of attack can not be imported identical. If a blade angle of attack at the entrance reaches a critical value, the first place on the blade stall, but not all "Small Cooling Fan" blade stall occurs simultaneously, this phenomenon be continued, so that caused the stall clogged area along with the impeller rotating in the opposite direction to promote, which produce the so-called "rotating stall" phenomenon. "Small Cooling Fan" into the zone run unstable conditions will produce a number of rotating stall area to the impeller.

Back to: Industry news

+86-0769-83660708

Home Product News Contact